Scheda corso
NovaNext Training / EPI Data Center / EPI Data Center Training Framework / Certified TIA-942 Lead Auditor (CTLA®)

Certified TIA-942 Lead Auditor (CTLA®)

Codice
CTLA
Durata
3 Giorni
Prezzo
4.995,00 € (iva escl.)
Lingua
Inglese
Modalità
Virtual Classroom
Corso in aula
       

 

Schedulazione
Luogo Data Iscrizione
Virtual Classroom 10/10/2024

The CTLA® is a 3-day course designed to provide the knowledge and skills to become a lead auditor who is able to independently conduct ANSI/TIA-942 conformity audits.

The course contains lectures and a variety of business cases and testing the aspiring auditor for his/her auditing capabilities. 

Lead auditors will determine the conformity or nonconformity of a data center to the requirements of the ANSI/TIA-942. As such, the examination is one of the toughest exams in the data center industry.

 

Prerequisiti
  1. A valid CTDC® – Certified TIA-942 Design Consultant Certificate

AND

2.A valid CTIA® – Certified TIA-942 Internal Auditor Certificate or a valid ISO-9001 or ISO-27001 Lead Auditor Certificate

 

Obiettivi
  • Describe the ANSI/TIA-942 audit scheme
  • Describe the different certification programs
  • Define an ANSI/TIA-942 audit program
  • Review design drawings for conformity to the standard
  • Judge audit evidence to be a CAT-1, CAT-2, OFI, RFI
  • Create an audit report that conforms to TIA requirements
  • Review a CAR – Corrective Action Report
  • Understand the requirements and process for issuing certificates
  • Describe the requirements for certification maintenance

 

Destinatari

The audience for this course is any professional who aspires to become a TIA-942 Lead Auditor.

Please note that the CTLA® certification does not allow the person to conduct a third-party audit and issue statements/letters/certificates unless he/she works for a TIA Accredited Licensed Certification Body and meets the other obligations as laid down in the auditor accreditation rules of TIA.


 

Contenuti

TIA-942 Accreditation Scheme

  • The ANSI/TIA-942 accreditation scheme
  • Standards
  • SDO – Standards Development Organization
  • TC/SC – Technical Committee / Sub Committee
  • Standards Development Process
  • Scheme Owner
  • Audit Organizations (RCB, CB, CAB)
  • Accreditation Body (AB, NAB)
  • Roles within a CB

Audit and Certification Process

  • Overview of audit process
  • Initiate audit
  • Prepare for audit
  • DCDV – Data Center Design Validation
  • DCCC – Data Center Conformity Certification
  • Report writing
  • CAR – Corrective Action Report
  • Issuance of certificates
  • ANSI/TIA-942 certification for data centers
  • Certificate maintenance
  • Audit steps duration overview

Audit Planning

  • The audit program
  • Planning the schedule
  • Audit preparation
  • Opening Meeting
  • Exercise: Creating an audit program, opening meeting presentation

Rating Levels Audit Criteria

  • High-level audit criteria considerations
  • High-level design requirements (Architectural, Electrical,
  • Mechanical, Telecommunication)
  • Rated-1
  • Rated-2
  • Rated-3
  • Rated-4

Recap on Nonconformity Classification

  • Nonconformity classi­cation
  • Major nonconformity
  • Minor nonconformity
  • OFI – Observation Form Improvement
  • RFI – Request For Information
  • Grading of nonconformity

Site Location & Architectural Audit

  • Key considerations

Fire Safety Audit

  • Key considerations

Physical Security Audit

  • Key considerations
  • Exercise: Review site planning, floor planning, physical security, ­fire safety

Electrical Audit

  • Key considerations
  • Exercise: Review SLD – Single Line Diagram

Mechanical Audit

  • Key considerations
  • Exercise: Review SLPD – Single Line Piping Diagram, fuel supply

Telecommunications Audit

  • Key considerations
  • Exercise: Network routing review

Closing Meeting

  • Closing meeting
  • Exercise: Closing meeting presentation

Preparing and Distributing the Audit Report

  • Audit report requirements
  • Audit report distribution
  • Retention of documents
  • Exercise: Creation of audit report

CAR Management

  • Follow-up action on audit report
  • History log of nonconformity
  • Criteria for issuing a conformance certificate
  • Review of a CAR
  • Exercise: Review CAR response

Certification and Certification Maintenance

  • The full audit cycle
  • Surveillance audit
  • Recertification audits
  • Issuing of the TIA-942 DCDV/DCCC Certificate
  • Requirements of the certificate
  • Registration of the certificate